Logo

Performance of square reinforced concrete columns externally confined by steel angle collars under combined axial and lateral load

Pudjisuryadi, Pamuda and Tavio, and Suprobo, Priyo (2015) Performance of square reinforced concrete columns externally confined by steel angle collars under combined axial and lateral load. Procedia Engineering, 125 (2015). pp. 1043-1049. ISSN 1877-7058

[img]
Preview
PDF
Download (7Mb) | Preview
    [img]
    Preview
    PDF
    Download (1543Kb) | Preview
      [img]
      Preview
      PDF (peer review)
      Download (62Kb) | Preview

        Abstract

        Providing good ductility has become research interest in the area of seismic resistant structures. Particularly in Reinforced Concrete (RC) structure, such ductility is commonly achieved by providing good confinement. Confinement can be conventionally provided by internal stirrups, and also additional external elements which are commonly used as strengthening or retrofit works. Attaching external steel collars on concrete columns is one of many techniques in enhancing the ductility. In this study, performance of such retrofitting method is investigated through laboratory experiment. Totally five specimens are built for this investigation. The first two specimens (CS1-1, and CS1-2) are control specimens, which are conventionally confined by stirrups. The other three specimens (S1-3, S1-4, and S1-5) are only confined externally with the steel angle collars. All five specimens are tested under combined axial and lateral load. The axial load is kept constant at 30% of plain concrete axial capacity to model the gravity load. The lateral load given is according to ACI 374.1-05 quasi-static cyclic loading protocol. Lateral load resistance is recorded throughout the cyclic loading, and plotted against the corresponding lateral displacement. Results show that specimens with smaller volumetric ratio of confining element suffered brittle failure (poor ductility). Specimens with adequate confinement show good deformability and ductile failure. In conclusion, the retrofitting method by providing external steel angle collars is very promising.

        Item Type: Article
        Uncontrolled Keywords: Confinement; Cyclic Loading; Retrofit; Square Concrete Column; Steel Collar
        Subjects: T Technology > TA Engineering (General). Civil engineering (General)
        Divisions: Faculty of Civil Engineering and Planning > Civil Engineering Department
        Depositing User: Admin
        Date Deposited: 12 Jan 2016 18:30
        Last Modified: 05 Nov 2021 17:07
        URI: https://repository.petra.ac.id/id/eprint/17230

        Actions (login required)

        View Item