To meet the urgent need for transmigration and to displacements due to natural disasters, prefab housing system is required for fast
construction. This study proposed a joint system to connect footings, concrete column / pedestal, and the tie beams. From four
types of connections two were deemed appropriate. A prototype, 2 x 2 x 2 m, was built for this purpose and tested for the
reliability of the connections. It appears that the connection could resist a horizontal force of 10% the column load and able to
withstand a diferential settlement of 2 cm. Erection with simple tools to assemble the components of the prototype only needs less
than 6 hours by three laborers. Factory made components will speed up the installation.