Abstract

The 2006 Yogyakarta earthquake resulted in collapse of several traditional buildings in Yogyakarta, including joglos.
This fact indicates that joglos are quite vulnerable to low-frequency ground shaking. The stability and rigidity of a joglo
building are provided by the core of the building, i.e. the rong-rongan structure, in which connection of sakaguru (the
column)-sunduk (the long span beam)-kili (the short span beam) has a rigid characteristic. This rigid rong-rongan structure
behaves elastically during an earthquake event, and attracts large inertia force. This research aims to increase the structure
performance of the rong-rongan by adding SANTEN-fuse, an earthquake vibration damper, and by changing the joint
connection of sakaguru-sunduk-kili to be that of a pin connection, but not changing the physical appearance of rong-rongan.
Santen, whose function is to transfer the load of the roof from blandar to sunduk and from pangeret to kili, is modified so that
it has frictional damper characteristic. This SANTEN-fuse can resist shear force up to certain level before it slides and
acting as a damper. With the reduced stiffness, which leads to reduced inertia force, the overall structural responses are
expected to be lower. An experimental quantitative method was used by doing a simulation using SAP2000 software to
verify the idea. The pendopo dalem Yudonegaran a joglo house in Yogyakarta was chosen as a case study. Non-linear time
history analysis was conducted. Simulation results showed that the proposed modification of rong-rongan structure by using
SANTEN-fuse, performed better than the original rong-rongan structure.

Item Type: Article
Uncontrolled Keywords: Rong-rongan; SANTEN-fuse; non-linear time history analysis; structural responses
Subjects: N Fine Arts > NA Architecture
T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TH Building construction
Divisions: Faculty of Civil Engineering and Planning > Architecture Department
Depositing User: Admin
Date Deposited: 10 Nov 2015 13:34
Last Modified: 28 May 2022 04:45
URI: https://repository.petra.ac.id/id/eprint/17394

Actions (login required)

View Item
View Item